and view the COBOL source code for this numeric field conversion example. In my previous tip, I introduced aspects to consider when importing data from This video shows the format in which numeric data is stored in Zoned decimal (conventional) and packed decimal (COMP-3) format. Alternate explanation: person doing the posting has absolutely no clue about internal formats of packed decimal and floating point numbers? This suite of programs is provided as a COBOL example of one of the possible solutions to the problem of determining the actual format, content and length of a numeric field and converting to a different format. and a Script Component. If doing it that way, you should check that the decimal point is a decimal point, and you should check that your numeric fields are numeric. Moving Numeric to COmp 3 - IBM Cobol - IBM Mainframe Forum Why is comp-2 mentioned? I want to convert packed decimal to numeric or zoned decimal. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. The Source Field is defined as a Binary (or COMP) field with 6 digits and 3 decimal positions. This numeric structure is the default numeric for COBOL and may be explicitly defined with the "USAGE IS DISPLAY" clause. SQL data types, SQLLEN values, and SQLTYPE values that the precompiler uses for host variables in COBOL programs. I just wanted to know, do we have any tool or utility through which we can do the same. It's simply. But as I told you in my The following is the WORKING-STORAGE definition for the result field. The hexadecimal information is (highlighted in green) The possible translated, displayable EBCDIC characters are (highlighted in blue). We have made a significant effort to ensure the documents and software technologies are correct and accurate. we need to select DT_BYTES as the Data Type; and 1 and 6 for its lengths This way we can have the decimal portion of the number separated from the full number. For example to store an numeric field of value 987 we would required 3 +1 divided by 2 = 2 Hence an Comp-3 field of length 2 bytes can store a value of +999 to -999 as the limit. Since we are going to perform This group of test cases will show the process for converting a packed-numeric format (COMPUTATIONAL-3 or COMP-3) to a text string or display format. The Source Field is defined as a BINARY (or COMP) and the result fields are "USAGE IS DISPLAY" or a numeric edited field. This is also true for external decimal (DISPLAY and NATIONAL) types that are converted by the compiler to packed decimal for COMPUTE statements. Packed numbers are amongst the hardest data sets to import into a SQL Server Link toan Evaluation zPAK Optionthat includes the program members, documentation and control files. take a look at. Morevoer i got SOC7 abend. This test case will show the process for converting a zoned-decimal-numeric format to a display (or zoned-decimal) format. What is the purpose of this D-shaped ring at the base of the tongue on my hiking boots? My code is GPL licensed, can I issue a license to have my code be distributed in a specific MIT licensed project? This halves the storage requirements compared to a character, or COBOL "display", field. Creating and Using Files: Data Types and Data Storage and view the COBOL source code for this numeric field conversion example. Format: label PACK D 1 (L 1 ,B 1 ),D 2 (L 2 ,B 2 ) - Packs the L 2 byte zoned decimal number at D 2 (B 2 ) and stores it as a L 1 byte packed decimal number at D 1 (B 1 ) - The packing process: 1. Services. For example to store an numeric field of value 987 we would required 3 +1 divided by 2 = 2 Hence an Comp-3 field of length 2 bytes can store a value of +999 to -999 as the limit. warning: turn off your caps lock. The following PROCEDURE DIVISION statement shows how to convert from a ZONED-DECIMAL to a DISPLAY (with SIGN TRAILING SEPARATE) numeric value'. Atlast divide the decimal-total by 1000 and add it to integer-part. Color Associations: The light-green boxes are unique to SIMOTIME Technologies using an IBM Mainframe System or Micro Focus Enterprise Developer. PIC is "picture" In the world of programming there are many ways to solve a problem. A variety of numeric formats are used on an IBM Mainframe System, a Windows System, a UNIX System or a Linux System. The rest of the code parses theString into theValue. Conversion of NUMERIC field to PACKED DECIMAL -IBM Mainframes A suite of Bash Script Files is provided to run the jobs on a Linux or UNIX System with GnuCOBOL (formerly known as Open COBOL) being used to compile and execute the COBOL Programs. This section describes the three (3) Windows Command Files that will be used to set the environment and execute the COBOL programs that perform the sample numeric field conversions. Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? the COBOL Routine for Example-304 If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the icon. A good place to start is Little Endian - within a sixteen or thirty-two bit word the bytes at lower addresses have lower significance. Lemme know what do you think. Short story taking place on a toroidal planet or moon involving flying. Asking for help, clarification, or responding to other answers. Is it possible to create a concave light? The following is a list of frequently asked questions about processing numeric fields and the impact of the various numeric types. Refer to Caveat, this was just freehand, I haven't tried compiling it. Move X (05) to packed field S9 (10) COMP-3. Not the answer you're looking for? What is the purpose of non-series Shimano components? Move packed field to X (05) (here I got value as x'0123450000') Converting packed to string:-. Refer to The three most common mainframe numeric encoding formats are Zoned-Decimal, Packed-Decimal and Binary. What video game is Charlie playing in Poker Face S01E07? This example also illustrates how to display the actual hexadecimal (or Hex Dump) content of a numeric field using a callable dump routine. Each picture character represents one . The binary strings will be bypassed, the numeric strings will be processed based on their numeric type and the text strings will be converted from EBC to ASC based on a user selected conversion table. Browse the Inputs and Outputs Tree by expanding the Flat File Source Output PD: Input format in Packed Decimal TO=ZDF: output format to be in all numerics TO=ZD: output format to be in all numerics with an alphabet LENGTH=n: If you want to override the output length, specify as n. Example. Refer to You know how Cobol has these field definitions for numbers like PIC 9999v99 and stuff. Long winded but very straight forward. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. The source field content is already in a display format. Is there a single-word adjective for "having exceptionally strong moral principles"? For eg, WS-VAR S9 (3) COMP-3. 80, Jubilee Hills, Hyderabad-500033 router bridge mode explained + 91 40 2363 6000 how to change kindle book cover info@vspl.in You need two COBOL data structures, aka. If the packed decimal is 0x11234D. Making statements based on opinion; back them up with references or personal experience. At the end of the exercise variable Y contains something that is readable and makes sense to the normal human eye. The following is an example of the Dump information produced on an IBM Mainframe or Micro Focus Mainframe Express on the PC that works with EBCDIC. The standard signs are used: hexadecimal F for positive numbers and hexadecimal D for negative numbers. This represents a number +6150000 with picture clause of S9(7) COMP-3. Can I tell police to wait and call a lawyer when served with a search warrant? To subscribe to this RSS feed, copy and paste this URL into your RSS reader. much higher than nowadays, it was a wise decision to implement packed numbers at Enter 2 and 3 in the TO section of the panel, for example: CA File Master Plus -- Reformat your.CONVERT.LIB(REFORMAT), ------------------------------------------------------------------------------. Here is a sort card to convert packed decimals to zoned decimals. IBMMainframes.com is not an official and/or affiliated with IBM. Tab. How to convert 'PD' to 'ZD'. A job script may be defined as a text file containing job setup information followed by job steps that identify programs to be executed along with parameters unique to the job step. Considering that back in a day the cost for storage and memory was byte [] pd = args [0] .getBytes () will build a byte array = {0x11, 0x23, 0x4D} this will result in -11234. Each byte has two nibbles, and each nibble is indicated by a hexadecimal character. In case of the above question to move the decimal portion of the number need to define an variable which can store only the decimal portion and move the value to that field which would hold just the decimal portion. ** The 'V' is an implied decimal point. EZT - Data conversion from Alphanumeric to Packed decimal - CA-Easytrieve This test case will show the process for converting a binary numeric format to an edited numeric format. Packed Decimal Data. Example: Data: begin of itab occurs 0, ebeln like ekko-ebeln, ebelp like ekpo-ebelp, menge (15) type p decimals 2, netpr (15) type p decimals 2, end of itab. I think the problem are in this columns : Actually Im usingbyte stream [DT_BYTES] format in flat file source andnumeric [DT_NUMERIC] in script component. By: Daniel Farina | Updated: 2015-01-20 | Comments (7) | Related: More > Integration Services Data Flow Transformations. Get alphanumeric string redefined into two numeric fields to hold and process decimal part and integer part individually. The following is the WORKING-STORAGE definition for the result field. If the definition size matches there shouldn't be any truncation. Find centralized, trusted content and collaborate around the technologies you use most. Dictionary debit type category debit value debit, to debit, to debit-side settlement debit/credit amount debited interest debiting and crediting an account debits debits and credits debits/credits indicator debt discount debt instrument debt instrument debt register debt to total capital debt-equity ratio debtor debug debugging debugging . bPacked (Byte Array): A byte array containing the packed number to be converted to decimal format. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration. Yes, for a fixed format define a structure accordingly. This group of test cases will show the process for converting a zoned-decimal-numeric format (USAGE IS DISPLAY) to a display format. I added a brief description This allowed programmers to economize space by using half of the size for numerical Packed decimal conversion - Java - Coderanch For the Category and Balance fields data we cant handle its content as simple text anymore, we need to perform analysis COBOL Computational Fields: comp, comp-3, packed decimal, binary - A Equivalent SQL and COBOL data types - IBM Using DFSORT OUTREC options you can achieve the same. At the end of the exercise variable Y contains something that is readable and makes sense to the normal human eye. You need to programmatically account for it. Enter 2 and 3 in the TO section of the panel, for example:CA File Master Plus -- Reformat your.CONVERT.LIB(REFORMAT) COMMAND ===> SCROLL ===> CSR FROM Record ------------ CPYBK#O1 of your.CONVERT.LIB --------------Num Field Name Pos Format Row 1 of 3 1 DATAREC1OLD 1 78 2 FIELD1-PCK 1 P 8.2 3 FILLER 7 C 72 *************************** Bottom of Record Layout *************************** TO Record ------------ CPYBK#N1 of your.CONVERT.LIB --------------Num Field Name Pos Format Reformat Row 1 of 3 1 DATAREC1NEW 1 80 2 FIELD1-NUM 1 N 6.2 2 3 FILLER 9 C 72 3 *************************** Bottom of Record Layout ***************************After pressing enter the numbers will be automatically translated to the field names.Press PF3 and type E now.You will see the JCL now. How to convert Python variables into equivalent cobol group variables? Determining the Digit Length of a Packed-Decimal Field - IBM If an item declared as COMP-3, the item appears in storage in packed decimal format. For. Explanation: For a comp-3 packed field specifies the number of digits after unpacking. Hope you could figure out. ("11 REFORMAT Convert file from one record layout to another"). Refer to Can we move alphanumeric to numeric in cobol? initialize array with values and view the COBOL source code for this numeric field conversion example. The following is the WORKING-STORAGE definition for the source field. If you have read my or you can use a SORT card to convert the packed value to numeric. This is the "official" BCD packed format of the COBOL standard. Explore Why is comp-2 mentioned? '0.450' as numeric decimal and do Converting Packed decimal S9 (11)V99 to unpacked Decimal -IBM Mainframes The following is the mainframe JCL required to run the jobs in a ZOS oriented, Mainframe environment. Moving Numeric values between variables in Easytrieve The zone and numeric digit of the rightmost byte of the zoned decimal number are reversed and placed in the . Downloads and Links to Similar Pages If the spaces were not there, the ABCDEF would not give you a problem, but would not give you the results you expect as the would be erroneously interpreted as digits. SourceForge is an Open Source community resource dedicated to helping open source projects be as successful as possible. . 2. So an 7 digit numeric number would require 7 +1 = 8 / 2 = 4 byte in size. I need to convert the values of packed decimal fields in itab to numeric type. Did this satellite streak past the Hubble Space Telescope so close that it was out of focus? If it is not, there will be an 0c7. This link requires an Internet Connection. Is there an existing gem or script that converts numbers to comp-3/packed decimal format? Although it only requests 18 digits (15+3), it gets 19 to make it an even length field with the sign (one digit added to the front to make it 10 bytes long on the file). The session will describe three of the popular numeric formats used with COBOL and IBM Mainframe systems. Moving packed-decimal (PIC S9(11)V99 COMP-3) to zoned-decimal (PIC S9(11)V99) is completely valid - providing the comp-3 data is properly signed numeric. The following is the WORKING-STORAGE definition for the source field. COMP-3 fields length is calculated as number of digits that we need to store + 1 divided by 2. The next is close to what you will see in a COBOLs Copy File (a file that contains Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? I tried the same, but didnt work. This number when packed, will be represented I need to convert 10-15 different files in the differernt JCL, So I want . > a hex character to represent a 3-digit insurance plan number (which in. As said above, UNSTRINGing and combining didnt work, but REDEFINES works! The Micro Focus Web Site So the last four bits of the number is used to store the sign of the number that is C or D so "C" represents the positive number and "D" represents the negative number. The next image should clarify the steps to follow. Atlast divide the decimal-total by 1000 and add it to integer-part. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact, Comment or Feedback section of this document. Is it possible to rotate a window 90 degrees if it has the same length and width? I've written a package just like this one and the packed fields are importing just fine. The fewer decimal positions of the result field will be rounded because of the ROUNDED keyword on the ADD statement. Save my name, email, and website in this browser for the next time I comment. So my advice to you is don't try bend COBOL into something that it is not. I know two methods for doing that. Joe, it is WS-EDITED-NUMBER from the REDEFINES which is being MOVEd, so no spaces. Just define WS-DEC-PART as PIC V999 and ADD. of them. Using Kolmogorov complexity to measure difficulty of problems? do so, just right click on the Flat File Source and select Show Advanced Editor data type, but as you will see further on, it is not enough. it doesn't exist on the file, but COBOL knows that it's there for rounding and such. converting string to pack decimal form - IBM Cobol - IBM Mainframe Forum Here I used SORT FIELDS=COPY is equal to OPTION COPY. and view the COBOL source code for this numeric field conversion example. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers. available from SourceForge. If you are running in CICS, you could use the BIF DEEDIT function -- that will leave you with "00.450". How to convert a alphanumeric string into numeric decimal in COBOL Studio Editor gives us a Class Template to add our code onto it. This is because, MOVE will work fine, if the hexadecimally stored values are compatible. Converting unpacked Packed Decimal Comp-3 data into doubles. Script Component has encountered an exception in user code : Project name: SC_502c8f1c0d6b40d7929990353c01db83, at System.Data.SqlTypes.SqlDecimal.ConvertToPrecScale(SqlDecimal n, Int32 precision, Int32 scale), at Microsoft.SqlServer.Dts.Pipeline.PipelineBuffer.SetDecimal(Int32 columnIndex, Decimal value), at Microsoft.SqlServer.Dts.Pipeline.PipelineBuffer.set_Item(Int32 columnIndex, Object value), at Microsoft.SqlServer.Dts.Pipeline.ScriptBuffer.set_Item(Int32 ColumnIndex, Object value), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.ScriptMain.Input0_ProcessInputRow(Input0Buffer Row), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.UserComponent.Input0_ProcessInput(Input0Buffer Buffer), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.UserComponent.ProcessInput(Int32 InputID, PipelineBuffer Buffer), at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer buffer).