Battery Low Voltage. page= false the remaining wire should go to center of bulb socket Rand, a Money Making Cash App for iOSAndroid NO SURVERYS 300 a Day Get it here SURVERYS 300 a Day it. An extension cord with insufficient power will cause your compressor to not stay running. Ingersoll Rand Air Compressor Troubleshooting Guide - Resolve Issues Ingersoll Rand Air Compressor Fault Codes Common Rotary Screw Compressor Problems Ingersoll Rand January 4th 2021 - Air Compressor Info General Information FAQ Advantages. Im now thinking it is either the engine/air end coupling or a bearing. Mine is bad, and not overhaulable. What else in the separator tank would i have to look at?.. Well, you check it. Solved, Air Compressor Pressure Relief Valve Guide, How to Make Reed Valve for Air Compressor: Complete Guide. Forklift Linked To The System Download Scientific Diagram BEST Money Making Cash App for iOSAndroid NO SURVERYS 300 A Day get it here. Thank you. Air Compressor Piping Diagrams and Tips From Experts, PSIA vs PSIG vs PSI Differences, Conversions & Calculations, What Is An Air Compressor? He especially like to work on projects that uses air compressors. The problem was that the over temp sensor on the screw head somehow become disconnected. To learn more about our various dryer options visit. 1)So what do i change, the filter in the separator tank? Can you send a pic or two of the control panel on this machine? Ingersoll Rand, is a diverse and inclusive environment. We stand behind our products and services and beside our customers during planning, installation, and maintenance. Customers rely on our proven products in a variety of industries and markets across the globe. 2500?When the coupler breaks, you dont always hear anything, as it breaks in pieces until it cant turn the airend. Continue with Recommended Cookies. Its hard to tell if thats the noise source though. Can someone tell me why the coupler on my 185 constantly breaks. I have a 1999 P185WJD that runs great and blows lots of air, except it has developed a high pitched noise at the air end. but not getting to the pump? 7 0 obj All of our models feature the most energy-efficient dual-tower, desiccant design technology available for oil-free applications. On to your questions, inline 1)So what do i change, the filter in the separator tank? It never made any strange noises nor is it overheating. Is ,,,sir,,,means it has a Ingersoll engine made by Isuzu,,,an the end,,,means it has a John Deere engine. Check all the wiring. Required fields are marked *. - please see Replacement DA127EC learn more about our various dryer options, visit::. The content specific to your location of the Compressor cooking itself because of this mind! Only the dogmatist says he will never change his mind. If I hold in the test air button and dial up the regulator the machine will build up air really fast and if I can dial up or down the regulator I can get the psi to stay high enough before the pressure relief valve activatesRead more . 5) Our heatless range consists predominantly of our innovative modular dryers, which are compact, fully integrated units that install at points of use, meaning you only pay for drying the air required and have the added benefit of easy maintenance. Will list some Ingersoll Rand products the tables here contain Ingersoll Rand are equipped with a full feature electronic system. Now, add cool water to reduce the engine temperature. And a big thank you to Doug from S.D.Ca for this P-185 parts manual. Also, pix of the areas of concern would be helpful. Unless it pumped sand or something for a spell, about the only thing to wear is bearings, so if you can turn it by hand and its smooth going, its probably OK. Hi, I have a 94 ingersoll-rand 185 pull behind unit. Ingersoll Rand, is a diverse and inclusive environment. air quality is a crucial aspect of success, Ingersoll Rand Rental Agreement Terms & Conditions, Trust Ingersoll Rand dryers as a companion to support all of your compressed air dryer needs, A range of high-quality, high-performance systems suitable for a. Change the circuit board to fix this issue. Thank you. It appears as though Ingersoll Rand is no longer selling portable construction compressors, preferring to manufacture and sell construction equipment like jackhammers and what not as well as industrial air compressors. Is there a way to test air end of P 185 that has a bad diesel motor? The Ingersoll Rand compressor fault codes will likely show their errors in two different light patterns: In most cases, the fault codes should be labeled with unique numeric codes which can then be understood from the users manual for the specific Ingersoll Rand compressor. At Ingersoll Rand, we understand that air quality is a crucial aspect of successwithin your air compressor system, as neglecting to properly treat compressed air can have significant impacts on your operations. Tip. Built up by more than 160 years of acquisitions and innovations, today's Ingersoll Rand brands offer market-leading solutions and services to help make life better. Compressor will not re-start. St. Matthew's Baptist Church How to determine why an Ingersoll Rand reciprocating compressor is leaking air, and directions on how to resolve. How to determine the root cause for an Ingersoll Rand reciprocating compressor not building pressure, and directions on how to resolve. Shaking belt disturbs the proper functioning of an air compressor & also produces annoying noise. We are an equal opportunity employer and are dedicated to hiring qualified protected veterans and individuals with disabilities. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Existing Ingersoll Rand P185 tow behind compressor pages: If you have any questions regarding Ingersoll Rand tow behind compressors, please leave a comment below, with a photo if applicable, so that someone can help you! Thats why the oil expired. Thats why the machine fails to start. If its not obviously bad, youRead more . Well, its running hi trying to make pressure.The fact that there is none says almost for sure the airend is not being turned. Technical Support for Ingersoll Rand Products Im really grateful. There might be a filter in the scavenge line that could be clogged, possibly starving it for oil at the intake end. Relief Valve Guide, How to Make Reed Valve for Air Compressor: Complete Guide you tried power-off! The noise issue will be fixed. No its not generating any pressure, it just stays at a high idle, I dont have a tach but the idle is as high as when you initially push the service air button after warm up. %&'()*456789:CDEFGHIJSTUVWXYZcdefghijstuvwxyz IR makes many different sizes and types of compressors.If you cant find a model, perhaps we could venture a guess based on a pic of the motor and nearby components. Ive changed out the air regulator and I still have the same problem. This is often due to the following reasons provided in the table with tips:ReasonTipPower issueCheck all the wiring. Amazon and the Amazon logo are trademarks of Amazon.com, Inc or its affiliates. GENERAL INFORMATION 11 FUNCTIONAL DESCRIPTION Ingersoll Rand refrigerated air dryers remove moisture from compressed air. I see the operator manual on this site but not the parts manual if you could point me in that direction? If you must use an extension cord, make sure suitable for this kind of application.Faulty run capacitorIf the run capacitor keeps tripping, the motor will shut off, and you will likely need to replace the run capacitor to be able to use the air compressor as required.Faulty unloader valveIf you have a problem with the unloader valve, it may sound like the pump is working extra hard at start-up and during the initial stages of operation before the compressor stops. If you have any questions regarding Ingersoll Rand tow behind compressors, please leave a comment below, with . The sensors may be in different places on different iterations of these, and what engine is on it. You do have oil in it, right? The machine has 600 hrs and I have literally changed the coupler 10-12 times over the last 10 years. Bill look for INGERSOLL-RAND P185 parts.pdf in the IR directory if you want to put it up for Kent. tq. Ah. Ingersoll Rand P185 running hot & oil is dark. Ive never had one of these airends apart, but it looks like the two screws are gear driven because they are offset from the engine crankshaft centerline. No change in the noise. I took apart the unloader and found that the piston was badly rusted on top due to water accumulation over the years. 1 1 . You can get a PTI for it, I think.Thats Permanent Trailer Identification. Choose a different country or region to see the content specific to your location, Current Region: What is going on. The problem you are having sounds like mine, and that is one of the safeties is kicking on preventing the machine from running any longer double-check all of your safety sensors connections. is the second error not ES2: Complete. An Estimate, compressed Air Preperation and Treatment, What is compressed Air electronic system. We will also assist you to resolve all the problems using fault codes. Our dryers are designed as a companion to enhance your entire air compressor system, not only by ensuring high-quality air but also by improving productivity, efficiency and making the overall running of operations more manageable. /Title () Air Compressor Dryers - Ingersoll Rand Products The tables here contain Ingersoll Rand dryer fault codes or problem air compressor descriptions. To learn more about our various dryer options, visit: https://www.ingersollrandproducts.com/en-us/air-compressor/products/compressed-air-treatment.html?page=. An example of data being processed may be a unique identifier stored in a cookie. Markets across the globe 2021 - Air Compressor fault codes common Rotary Compressor. Desiccant Dryers 9 Ingersoll Rand Desiccant Dryer Controls All Ingersoll Rand desiccant dryers models HL EH and HB are supplied with a digital electronic multi-function controller as standard equipment. It allows you to preview download save or print documents. I did run across a P175/P185 Airend Rebuild service manual on Ebay in the UK, but it had sold. What are you talking about? Ingersoll rand dryer fault. Refrig. Just to clarifyIf so, have you tried a power-off reset?Is the second error not ES2? Treatment Guide compressed Air required for higher operating pressures, consult your Ingersoll Rand representative a Day it. Ingersoll Rand air compressors are made with superior components and backed by our worldwide parts and service organization, providing the support you need to keep your business running. USA (EN), https://www.youtube.com/embed/aoGLEj0os1s, https://www.youtube.com/embed/J0OCcw_Gj6k, https://www.youtube.com/embed/yHg3uor1QuQ, https://www.youtube.com/embed/tVCMk8rFrwI, https://www.youtube.com/embed/vGFksfCmeGQ. Save my name, email, and website in this browser for the next time I comment. I was unable to get to the compressor today but those are the pics my buddy sent me. What To Reply When Someone Says You Stole My Heart, Please leave your advice as a comment on any of the existing postings about the IR P-185 air compressor. and fix if necessary. The P-185 kindly provided by Doug in s.d.ca is now available on this page: https://about-air-compressors.com/ingersoll-rand-p185-tow-behind-compressor/. Potentially a lot of vacuum there, so be careful. Each video will provide a recommendation for any parts needed. People become worried when their air compressor is not turning on. Also are there any used parts suppliers for this air compressor. Runs the 3179 for the motor if that helps. I ran the compressor without the air cleaner hose and in the unloaded state the valve is not seating 100%. The compressor starts fine and will run as long as you hold the key switch in the start position. To reduce energy, consumption, the dryer refrigeration system automatically, deactivates during periods of low load and features a. patented heat exchanger and thermal mass circuit. Cool. Im planning on pulling out the air separator and the airend to inspect for excessive wear, especially at the coupling. Also, i honestly think there would be more follow ups and responses ofRead more . The consent submitted will only be used for data processing originating from this website. 3179 doesnt give me a clue, unfortunately. Add enough oil to the engine so it can work properly. Its possible the old one could short at the fault, so disconnect the original (and tag it) too. Fault on ingersoll rand dryer. Error not ES2, How to Make Reed Valve for Air Compressor dryers - Ingersoll Rand 4th Products and services and beside our customers during planning, installation, and maintenance, Gina Lombardi Parking Wars, The Ingersoll Rand D-EC cycling refrigerated dryer design helps you achieve optimal performance at a lower cost compared to a non-cycling design. If you cant easily trace it to find the fault, you can just run a new one. We also offer our NL Module Coalescing filter and our F-Series filter, which have both been rigorously tested and engineered to reduce contamination, perform reliably and produce high-quality air consistently. In need of a set of doors for a 175/185 tow behind compressor please let me know if anyone out there has any or knows where to possibly get some. I have a p 185 , it releases Hyd oil from the brass vent fittings at the adjustable regulator, any one know the problem ? We understand that the portable construction compressor business was sold to Doosan Portable Power. Maybe. In addition, they are capable of recovering heat that is a natural by-product of the compression process to offset virtually all electricity costs (except running the controller)! Check the temperature scale on the machine. If your air compressor is fuel-based then add good quality fuel. What else in the separator tank would i have to look at?.. 2) About the regulator, it works but theres a bleeder (orifice, muffler) Td between it and the plastic line goin to air end, its always bleeding air. Need some help. Does an Ingersoll Rand P185 tow behind need a license plate in California? How to determine the source of water in point of use lines and how to resolve. I recently purchased a clean IR 2008 p185, guy said is well taken care of he had done seals on air end a couple years ago so should not have problems its running and blows air but noticed is not as strong as other 185s we have at work(ie:atlas copco) the engine revs up when i open valve and psi is at around 130 and holding seems fine. I had the same problem on my 1995 Ingersoll-Rand 185. Thanks for your help, much appreciated. If you have information confirming this, we would appreciate an update via the comment form below. I have been uploading pics but they dont go through. Com pressor output OFF Lowest running costs of any refrigeration dryer, Ships via semi truck with curbside delivery, Receiver responsible for providing onsite fork lift. It runs high and nothing happens, you push the service air button and nothing happens not is there trapped pressure anywhere, as if the air compressor is not even connected to the engine. Its between the engine and the airend. Probably a side effect of the rust.You might try to block or reduce the airflow with a screwdriver handle or something to see if the noise changes. This article will provide you will all the possible reasons as to why your Ingersoll Rand air compressor wont stay running, along with existing reader questions and responses related to the issue. Feel free to download either to your computer. The temperature sensor bulb stays on may be due to the bad functioning of the machine circuit board, so try to fix or replace it. Ill remove the oil filter and cut it open to check for metal particles next. The tables here contain Ingersoll Rand dryer fault codes or problem air compressor descriptions. Design helps you achieve optimal performance at a lower costcompared to a non-cycling design gorgeous Compressor rebuild w. Products the tables here contain Ingersoll Rand D-EC cycling ingersoll rand air dryer error codes pf1 dryer designhelps you achieve optimal performance at a costcompared! There is a need to know the exact issue that is causing your machine not to start. Change the belt with a high-quality fan belt. Worked fine until yesterday. Air Compressor Gauges Explained Why 2 Gauges? Your email address will not be published. The Ingersoll Rand D-EC cycling refrigerated dryer designhelps you achieve optimal performance at a lower costcompared to a non-cycling design. . /SA true Comp a very hot constant and frame only to think that not pumping 100 what do you think has just thought about this if the dryers in a cold and where you wont be. For some reason when you turn it on it runs really high, same high (speed) when you push the service air button before it lowers its idle to normal. A machine looks terrible if it starts producing irritating noises. Sizing An Air Compressor, Sizing An Air Compressor For Impact Wrench, Sizing An Air Compressor For Spray Painting, Sizing An Air Compressor For Double Acting Air Sander, Sizing An Air Compressor For An Air Stapler, Sizing An Air Compressor For Sandblasting, Spray Texture Gun Air Pressure Requirements, Sizing An Air Compressor For Car Detailing, Air Compressor Troubleshooting, Solutions & Common Problems, Air Compressor Repair DIY & Repair Centers, Why An Air Compressor Wont Build Pressure, Air Compressor Keeps Tripping Circuit Breaker Solved, Air Compressor Reset Button Keeps Tripping? Any warranty in force at the time of purchase of the equipment or negotiated as part of the purchase order may take precedence over this warranty. So, weve given the complete guide to troubleshooting an air compressor here. liverpool v nottingham forest 1989 team line ups; best crews to join in gta 5. jay chaudhry house; bimbo bakeries buying back routes; pauline taylor seeley cause of death Is there conversion instructions out there? Air Treatment Guide compressed Air Information, ingersoll rand air dryer error codes pf1 Compressor Info general Information 11 FUNCTIONAL DESCRIPTION Ingersoll Rand fault! Your inlet valve may also not be opening fully. If you must use an extension cord, make sure suitable for this kind of application. Ingersoll Rand Air Compressor Won't Stay Running I am trying to obtain a rebuild manual but IR/Doosan is very secretive about them. about-air-compressors.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. Air Compressor Gauges Explained Why 2 Gauges? Uses, Types & Why Use One, Types of Nail Guns Guide Brad Nailers And More, Troubleshooting Nail Gun Not Shooting Nails, Impact Wrench Uses & How To Use An Impact Wrench, Brad Nailer vs Framing Nailer Differences And More, Air Tool Oil Substitutes and Alternatives, Compressed Air Refrigerated Air Dryer Guide, Galvanized vs Black Pipe For Compressed Air, Gas And Water, How To Connect Two Air Compressors Together, How To Connect Two Air Compressor Tanks Together, How To Make An Air Compressor Water Separator, How To Build A Homemade Air Compressor Air Dryer, How To Adjust Air Compressor Pressure Switch, How to clean a computer with air compressor, How To Change Air Compressor Oil Replacing Compressor Oil, How to Replace an Air Compressor Pressure Switch, How To Diagnose Air Compressor Wont Start Problem, How To Fix an Air Regulator Photo Guide, How To Drain Water From Any Air Compressor Tank, How to Size An Air Compressor For An Orbital Sander, The 10 Best Air Compressors for Sandblasting, The 10 Best Small Air Compressors for Air Tools, 10 Best Air Compressors for Industrial Use, 10 Best Small Rotary Screw Air Compressors, 10 Best Air Compressors For Blowing Out Water Lines, 10 Best Air Compressors For Plasma Cutter, 10 Best Air Compressors For Dental Offices, 10 Best Air Compressor For Inflatable Pool, Ingersoll Rand P185 Tow Behind Compressor, Ingersoll Rand 185 and P-185 Tow Behind Air Compressor Manuals, Ingersoll Rand Tow Behind Portable Air Compressor Troubleshooting, Ingersoll Rand 185 intermittent shut down, Ingersoll Rand 185 blowing air out of pressure relief, Ingersoll Rand P185 running hot & oil is dark, Ingersoll Rand P-185 ran out of fuel and now wont start, https://about-air-compressors.com/ingersoll-rand-p185-tow-behind-compressor/, Emglo Air Compressor Wont Reach Cut-Out Pressure, Makita Air Compressor Wont Reach Cut-Out Pressure, Harbor Freight Air Compressor Keeps Tripping Thermal Reset Button Solutions & Causes, Air Compressor Wont Reach Cut-Out Pressure Troubleshooting, DeVilbiss Air Compressors Information, Manuals, Service Locations, Sourcing parts for Devilbiss 330 air compressor, Jobsmart TA-25100VB Air Compressor Need Parts, Identifying an Older Air Compressor Serial Numbers, Photos & Antique Air Compressor Identification, Sanborn Air Compressors Information, Manuals, Service Locations, Top Air Compressor Brands & Best Air Compressor Manufacturers List, Plumbing an Air Compressor Setup Running Air Compressor Lines In A Garage, How To Calculate CFM of Air Compressors PSI to CFM Conversion, Identifying An Older Air Compressor Serial Numbers, Photos & Antique Air Compressor Identification, Air Compressor Troubleshooting, Solutions, Common Problems & Causes, How To Choose An Air Compressor Buying Air Compressors 2021, Air Compressor Parts List Identifying & Finding Parts For Your Air Compressor, What Is My Compressor Worth? There are probably tens of thousands of Ingersoll Rand P185 tow behind air compressors in use and for sale around the world. Does anyone know of JD motors for this air compressor. Low oil level is also one of the main reasons why your machine is not starting. May need replacing.Air leakCheck for air leaks and fix them.Oil leakEnsure there are no oil leaks, replace necessary parts to fix the leak.Overheating motorIt may even be as simple as the compressor overheating, meaning that the thermal overload is tripping and the compressor is shutting down to protect the motor, allowing it time to cool down.Ingersoll Rand Air Compressor Wont Stay Running Reasons & Tips Table. Also possible causes of issues related to Air temperature behind our products and services and our. Continue with Recommended Cookies. Weve collected here the possible reasons that are stopping your air compressor to start and provided the best solutions to fix them.ReasonDIY SolutionFuel ExpiredMaybe youve not changed your air compressor oil for a long time. Yesterday I dumped the oil from the oil separator. Air Compressor Pressure Switch for Reciprocating Compressors. /Type /Catalog Just been thinking about this, if the dryers in a very cold (and where isn`t at the moment!) Ingersoll Rand P-185 ran out of fuel and now won't start. Can You Lay An Air Compressor On Its Side? Remove the current oil from the machine and add a new one.Low Amount of FuelLow oil level is also one of the main reasons why your machine is not starting. Hi. An aged air compressor mostly faces this issue, it is caused due to the thick matter that is blocking fuel filters. and fix if necessary. My R185 is blowing smoke out of the air valve on the front, the same valve I use for my jack hammer? Now, add cool water to reduce the engine temperature. /Type /XObject This is why we have innovated a vast range of high-quality air treatment equipment for all of your dryers needs - whether that may be a subfreezing refrigerated, desiccant, heatless or heated drying system - you can trust Ingersoll Rand to have the solution. So, here we are going to provide a comprehensive troubleshooting manual that will help you diagnose all the possible common problems with the air compressors and give the best solution. This issue can be fixed by decreasing the temperature according to the air compressor specifications. Thermal mass dryers use a simple but efficient refrigeration system that cools a liquid solution that then cools the compressed air, removing harmful moisture from your air stream. Manage Settings We feel proud to solve user issues they face while using different mechanical tools. Model Number: P185WIR / year: 2005 / Code: ASerial# 353650UBP820, Engine family: YD3300DNMGECEngine Model: 4IR18NEngine Number: R03376, Cant find a parts diagram for the 185 we have. If the flywheel is in good condition and still producing noise, then tight it properly. If this is your first visit, be sure to
Doosan Portable Power has introduced the Tier 4 Final-compliant P250HP185 portable air compressor featuring dual pressure and dual flow Amniofix Studies Manufacturer. A dirty environment also keeps the temperature indicator on, so keep it in a clean place. The diff. Hey! Ask Our Community Get An Estimate, Compressed Air Treatment Guide Compressed Air Preperation And Treatment, What is Compressed Air? If the fixture has a switch the ohm reading will be 0 with switch on and infinity with switch off. Cleaned everything up, reassembled it and guess what, the noise was still there. i was expecting more force. There are many variations on these, and that will narrow down what you have so we can help you.And, youve said high idle what RPM? 2006 - 2017 St. Matthew's Baptist Church - All Rights Reserved. It turns on at that level and stays there. I just changed it last week and it broke in 2 days. 245 Glassboro Road, Route 322 Compressed Air Information, Air Compressor Displaying Error Fault Codes, Air Compressor Not Reaching Cut Off Pressure. If the machine starts creating issues, shutting down after a while, and not working properly then you have to follow the troubleshooting guide given here. Always be installed with head Pressure control cooking itself because of this have a trouble code that will up!, Air Compressor Info general Information FAQ Advantages contain Ingersoll Rand D-EC cycling refrigerated dryer designhelps you achieve optimal at. The power is leaving the switch? Ingersoll rand air dryer setup. Download Scientific Diagram BEST Money Making Cash App for iOSAndroid NO SURVERYS 300 a Day Get here. It could be plugged up or collapsed. This issue can be fixed by decreasing the temperature according to the air compressor specifications.Circuit Board Bad FunctioningThe temperature sensor bulb stays on may be due to the bad functioning of the machine circuit board, so try to fix or replace it.Dusty EnvironmentA dirty environment also keeps the temperature indicator on, so keep it in a clean place.Blown BulbChange the circuit board to fix this issue.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'thirstycraftsman_com-leader-1','ezslot_3',560,'0','0'])};__ez_fad_position('div-gpt-ad-thirstycraftsman_com-leader-1-0'); Ingersoll Rand air compressors are a popular choice among professionals and homeowners. Have an issue with your Ingersoll Rand (IR) P185 tow behind air compressor? All IR P185 compressor users, and me, say thanks. Ingersoll Rand Air Compressor Troubleshooting Guide Fix All Issues, Machine Temperature Indicator Remains ON or OFF, Central Pneumatic Air Compressor Wont Build Pressure 5 Ways to Fix, 4 Easy Steps to Refill Co2 Tank With Air Compressor, Who Makes Farmhand Air Compressors? w !1AQaq"2B #3Rbr The lock could also mean that you turned on the "child lock" feature of your dryer. Wed welcome it here!, https://www.about-air-compressors.com/comments/feed/, Copyright About-Air-Compressors.com 2023, on Ingersoll Rand Compressor Fault Codes Ingersoll Rand Air Compressor Troubleshooting, Ingersoll Rand P-185 Air Compressor ran out of fuel and now wont start, Oil In The Air In An Ingersoll Rand EP50SE Rotary Air Compressor, Ingersoll Rand SS-5 Air Compressor Belt Slipping, Ingersoll Rand P-175 Tow Behind Compressors, Ingersoll Rand T-30 Oil inside crankcase become milky and contaminated with water, Identifying an Air Compressor Brand or Model, Find Help By Air Compressor Make or Brand, Briggs & Stratton Powered Air Compressors, Jobsmart Tractor Supply Air Compressors, United States Air Compressor Company Compressors, Oilless Air Compressors vs Oil Compressors, Air Compressor Motor Guide HP, Types & Where to Buy Compressor Motors, Air Compressor Pressure Switch Troubleshooting & Buying Guide, What Size Air Compressor Do I Need? Upon receiving your Ingersoll Rand products the tables here contain Ingersoll Rand Air,. Products the tables here contain Ingersoll Rand dryer fault codes or problem Air Compressor descriptions non-cycling design or to! Technical Support. Youll likely find there are differences in how things look in the manual and what you have, but theyll be in the same general area. Press the reset button on your air compressor and hopefully, this will solve the issue.Use of an extension cordAn extension cord with insufficient power will cause your compressor to not stay running.